<LOGO>
FM Transmitter Measurement Report
Created: 2024-02-11 05-07-55
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 5/5, 42 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
6 kHz 45 kHz 18623 0,1020
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,6 dBr -0,87 dBr 0,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 5:07, 11.02.2024
RT
"Zaostreno - Presne v polovine je lhuta, kterou maji letosni d..."
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 45 kHz MIN: 6 kHz % above 77 kHz: 0,1020 Acquired: 2024/02/11 5:07:52 Total samples: 18623 Equivalent time: 0:15:31 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 0,2 dBr MIN: -1,6 dBr AVE: -0,87 dBr % above 0,2 dBr: 0,0 Last value: -0,4 dBr (2024/02/11 5:07:52) 04:54 04:56 04:58 05:00 05:02 05:04 05:06 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality